3.2.1 Victim link
The victim parameter characteristics summarised in Table 6 should be entered into SEAMCAT.
Table 6: Characteristics of the victim link pair of receiver and transmitter
|
Parameters |
Value |
Units |
|
Operating Frequency |
1000 |
MHz |
|
Transmitter power |
30 |
dBm |
|
Receiver bandwidth |
200 |
kHz |
|
Tx and Rx antenna type |
Omni directional |
|
|
Tx and Rx antenna gain |
9 |
dBi |
|
Tx and Rx antenna height |
30 |
m |
|
C/I protection criteria |
19 |
dB |
|
C/(N+I) protection criteria |
16 |
dB |
|
(N+I)/N |
3 |
dB |
|
I/N |
0 |
dB |
|
Noise floor |
-110 |
dBm |
Each simulation workspace contains one and only one victim link.