Skip to main content

Recently Updated Pages

13.3 Edit and share library element

13 Library of scenario elements

When opening a library item from the workspace menu,  the following interface will appear (as an ...

Updated 1 month ago by ECO TECH

13.2 Import / export a library element in/from a workspace

13 Library of scenario elements

 Modification of existing (default) library elements as well as creation of new elements can be m...

Updated 1 month ago by ECO TECH

13.1 Library overview

13 Library of scenario elements

SEAMCAT library is a useful tool for creating and storing various elements that are part of a wir...

Updated 1 month ago by ECO TECH

Netiquette

Electronic Working Arrangements

There is a need to establish netiquette to ensure that communications in online tools are efficie...

Updated 3 months ago by ECO TECH

12.9.3 Interference Calculation Engine Control

12 Results 12.9 Interference calculations

 It allows to the calculation of the probability of interference for several ICE configurations (...

Updated 3 months ago by ECO TECH

12.9.2 Interference calculation GUI

12 Results 12.9 Interference calculations

When the simulation is finished, the dRSS and the iRSS vectors are stored. You may proceed to use...

Updated 3 months ago by ECO TECH

12.9.1 Introduction

12 Results 12.9 Interference calculations

The Interference Calculation Engine (ICE) is that part of the SEAMCAT architecture which calculat...

Updated 3 months ago by ECO TECH

12.8.3 Inspect selected element

12 Results 12.8 Cellular Structure

12.8.3.1 Detail When an element of the main plot is selected, i...

Updated 3 months ago by ECO TECH

12.8.2 Summary of event #n

12 Results 12.8 Cellular Structure

The “Summary of event#n” panel provide a few metrics on the number of users simulated Figure 268 ...

Updated 3 months ago by ECO TECH

12.8.1 Plot configuration

12 Results 12.8 Cellular Structure

The top part of the detailed system information screen contains a range of checkboxes used to con...

Updated 3 months ago by ECO TECH

Introduction

12 Results 12.8 Cellular Structure

When simulating CDMA or OFDMA systems, you will have access to the additional tab "Cellular struc...

Updated 3 months ago by ECO TECH

12.7 EPP results

12 Results

In case an EPP is used and it returns a set of result, they will also be included next to the sta...

Updated 3 months ago by ECO TECH

12.6 OFDMA output results

12 Results

The results of the OFDMA simulation are given in terms throughput loss of the OFDMA victim. Figur...

Updated 3 months ago by ECO TECH

12.5.3 CDMA results for cell selection algorithm

12 Results 12.5 CDMA output results

When the CDMA “cell selection” algorithm is simulated, the following output vectors are also avai...

Updated 3 months ago by ECO TECH

12.5.2 CDMA results

12 Results 12.5 CDMA output results

Once SEAMCAT has completed the simulation, the results are shown as displayed in Figure 261, when...

Updated 3 months ago by ECO TECH

12.5.1 CDMA capacity finding

12 Results 12.5 CDMA output results

During the pre-simulation part, the system estimates the load of the network as shown in Figure 2...

Updated 3 months ago by ECO TECH

12.4.6 Average active WSDs per frequency vector

12 Results 12.4 Spectrum sensing results

It provides the average number of active WSD per event for a specific frequency:                 ...

Updated 3 months ago by ECO TECH

12.4.5 Average e.i.r.p. per frequency

12 Results 12.4 Spectrum sensing results

It presents the average e.i.r.p. per event (dBm vs MHz) for all the active WSDs transmitting at a...

Updated 3 months ago by ECO TECH

12.4.4 Victim frequency vector

12 Results 12.4 Spectrum sensing results

The victim frequency vector (MHz) represents the frequency at which the victim device transmits p...

Updated 3 months ago by ECO TECH

12.4.3 WSD e.i.r.p.

12 Results 12.4 Spectrum sensing results

The actual selected e.i.r.p. (dBm) at which the WSDs are allowed to transmit as the result of the...

Updated 3 months ago by ECO TECH