2.16 Testing propagation models A sanity check on the suitability of a propagation model can be done by clicking on in the main menu of SEAMCAT, by clicking on the icon ( ) of the toolbar or by pressing < CTRL +SHIFT+M>. With this feature, it is possible to evaluate the result while using a certain propagation model.   Figure 50: Access to testing propagation model   For that, choose the propagation models to compare them. It is possible to compare 2 or more propagation models with this interface. Figure 51 shows that the SEAMCAT resulting attenuation from the free space is 101.47 dB where the free space path loss is defined as:         (Eq. 16) where d is given in km and f is given in MHz. This results in Figure 51: Illustration on to check the propagation model results   If one parameter is chosen as a distribution (for instance distance), then the button is activated. Pressing it enables you to plot your results according to a sorted X-axis from min to max. Finally click on or (depending which one is active) to view the results. If no results are displayed, check the Java console for any error messages. Figure 52: Example comparing 2 propagation loss using the “generate sorted samples”. You can display the vector in linear or logarithmic scale